Electrical Boot Camp · Module 05

Continuity & Resistance

A6 · General Electrical6 minPower off · isolated
01 The Concept

The ohmmeter's two jobs — and the one rule that keeps it honest.

The ohmmeter sends its own tiny current through a part to measure resistance, so it only works with the circuit dead and the part isolated. Two jobs: continuity — is there a complete path? (low ohms = yes, OL = open) — and resistance — does a component measure within spec? Coils, sensors, and resistors all have a spec window; too high means an open/high-resistance winding, too low means a short.

Power OFF, part isolated

Never ohm a live circuit — you'll get a false reading or damage the meter. And isolate the part: leaving it in the circuit lets parallel paths read lower than the real value.

Reading the window

OL / infinite = open. Near 0 = short or a plain wire. A component reads a spec range — compare to the service data, not to zero.

⚑ When ohms lie

A corroded connection can read near 0 Ω cold yet drop 1–2 V once real current flows. The ohmmeter's test current is far too small to reveal it. For a weak or intermittent complaint, trust a voltage-drop test under load (Module 00), not the ohmmeter.

02 The Ohmmeter Bench

Pick a part to test. Watch the reading — and try flipping the circuit power on.

Ω · Resistance
0.2
ohms
Circuit power
03 What If…

Reason first, then reveal.

?A connection reads 0.3 Ω on the ohmmeter, so a tech calls it good — but the circuit is still weak. What did they miss?
?You measure a coil's resistance while it's still wired into the harness and get a suspiciously low number. Why?
?An ignition coil primary reads OL. Spec is 0.4–0.8 Ω. Good or bad?
04 Practice

ASE-style. Pick an answer to see why.

05 Recap
  • Ohmmeter = circuit dead, part isolated. Never on a live circuit.
  • Continuity: low ohms = complete path, OL = open.
  • Components read a spec window — too high = open/high-R, too low = short.
  • In-circuit readings run low from parallel paths; isolate first.
  • Near-0 cold can still drop volts under load — use a voltage-drop test for weak/intermittent faults.
Redline · Electrical Boot Camp · Module 05